Datwyler Fiber Patch Cords

Singlemode G.652.D BLO and multimode OM4 and OM5 fiber patch cords from Datwyler. LC, SC, LCD, and SCD termination options with PC, UPC, and APC polishes for data center and enterprise applications.

6 products
Datwyler LC/PC to SC/APC OS2 duplex fiber patch cable with yellow LSZH jacket
Datwyler

Duplex OS2 Singlemode LC/PC to SC/APC G.652.D LSZH Fiber Patch Cable

LSZHOS2DuplexLC to SC
Length:
+2 more+3
In stock
€20,82excl. VATIncl. VAT €25,19
Datwyler LC/APC to SC/APC OS2 duplex fiber patch cable with yellow LSZH jacket
Datwyler

Duplex OS2 Singlemode LC/APC to SC/APC G.652.D LSZH Fiber Patch Cable

LSZHOS2DuplexLC to SC
Length:
+2 more+3
In stock
€20,82excl. VATIncl. VAT €25,19
Datwyler LC/APC to LC/APC OS2 duplex fiber patch cable with yellow LSZH jacket
Datwyler

Duplex OS2 Singlemode LC/APC to LC/APC G.652.D LSZH Fiber Patch Cable

LSZHOS2DuplexLC to LC
Length:
+5 more+6
In stock
€20,82excl. VATIncl. VAT €25,19
Datwyler LC/PC to SC/PC OS2 duplex fiber patch cable with yellow LSZH jacket
Datwyler

Duplex OS2 Singlemode LC/PC to SC/PC G.652.D LSZH Fiber Patch Cable

LSZHOS2DuplexLC to SC
Length:
+5 more+6
In stock
€20,82excl. VATIncl. VAT €25,19
Datwyler LC/PC to LC/PC OS2 duplex fiber patch cable with yellow LSZH jacket
Datwyler

Duplex OS2 Singlemode LC/PC to LC/PC G.652.D LSZH Fiber Patch Cable

LSZHOS2DuplexLC to LC
Length:
+5 more+6
In stock
€20,82excl. VATIncl. VAT €25,19
Datwyler LC/PC to LC/PC OM4 duplex fiber patch cable with heather-violet LSZH jacket
Datwyler

Duplex OM4 Multimode LC/PC to LC/PC 50/125 µm LSZH Fiber Patch Cable

LSZHOM4DuplexLC to LC
Length:
+5 more+6
In stock
€20,82excl. VATIncl. VAT €25,19

About Datwyler Fiber Patch Cords

Datwyler fiber optic patch cords cover singlemode G.652.D BLO bend loss optimized and multimode OM4 and OM5 fiber types. Available in LC duplex, SC duplex, LC simplex, and LC quad formats with PC, UPC, or APC polishes depending on the application requirements.

Singlemode vs Multimode

Use OM4 or OM5 multimode patch cords for short reach data center applications up to about 550 meters at 10G, or 150 meters at 40G and 100G with parallel optics. Use G.652.D BLO singlemode for longer distances, between rooms, or for any deployment where future bandwidth growth is expected beyond 100G.

Polish Types

APC (Angled Physical Contact) polishes are required for video applications and high power optical signals because they reduce back reflections to below 60 dB.

UPC (Ultra Physical Contact) is the standard for data and telecom use. Never mix APC and UPC connectors at the same mating point because the angled and flat geometry will not seat correctly and will damage the ferrule.

Delivery and Support

Stocked in standard lengths from 1 m to 10 m. Custom lengths and pre tested assemblies available on request. Same day shipping before 16:00 CET from our Dutch warehouse.